Home βΊ New York βΊ FDNY S-13 Standpipe Systems
Quick answer
The FDNY S-13 / S-14 exam has 75 multiple-choice questions, taken on a touch-screen computer at FDNY headquarters in Brooklyn, and you need 70 percent (53 of 75) to pass. FDNY provides the inspection and testing reference guides during the exam. The application fee is $25 and renewal is $15 as of October 2026; the certificate lasts three years.
About the exam
FDNY S-13 / S-14 Standpipe Systems Certificate of Fitness Exam
Standpipe systems carry water to hose connections on every floor so firefighters can fight fires in tall and large buildings. In New York City they must be inspected, tested and maintained by a person holding an FDNY S-13 Certificate of Fitness, employed or contracted by the building owner. Buildings with a multi-zone standpipe system also need an S-14 holder in constant attendance. Building engineers, superintendents and fire suppression contractors take this exam.
The exam is 75 multiple-choice questions at FDNY headquarters, and you need 70 percent. FDNY does not publish a time limit for the S-13; it says only that the test is timed. The March 2024 booklet covers the owner's and impairment coordinator's duties, out-of-service procedures with tags and discs, record keeping and defect reporting, who may do which work, standpipe classes and types, components and valves, water supplies, fire pumps and tanks, the NFPA 25 inspection, testing and maintenance frequencies, signage, FC 905 and Rule 905-01.
This bank is written from that booklet, and every answer cites its part and section. Combined sprinkler and standpipe systems also need an S-12 or S-15, which has its own exam. Our timed practice test draws questions in proportion to each topic's share of pages in the FDNY booklet (an estimate; FDNY publishes no topic weights).
Exam format
FDNY S-13 Standpipe Systems: questions, time and pass mark
| Item | Official exam | Status |
|---|---|---|
| Questions | 75 multiple choice, four options each | Verified Oct 2026 (S-13 booklet, Mar 2024) |
| Time limit | Timed, but FDNY does not publish the number of minutes for the S-13 | Not published by the agency |
| Pass mark | At least 70 percent (53 of 75) | Verified Oct 2026 (S-13 booklet) |
| Reference material | FDNY provides the inspection, testing and maintenance reference guides and activities chart | Verified Oct 2026 (S-13 booklet) |
| Requirements | Age 18 or older, two forms of ID, and a letter of recommendation from your employer (self-employed: a notarized letter) | Verified Oct 2026 (S-13 booklet) |
| Validity | 3 years; renewal $15 | Verified Oct 2026 (S-13 booklet; nyc-business.nyc.gov) |
The practice test above draws 50 questions with a 90-minute timer and a 70% pass mark. Practice mode lets you work one topic at a time with explanations after every answer, and the cheat sheet view lists every question and answer for review.
Cost and booking
Fees, where to take it and retakes
Apply and pay online, then take the exam on a computer at FDNY headquarters, 9 MetroTech Center, Brooklyn. The application fee is $25 as of October 2026. Renewal costs $15 every three years, with a $25 penalty for renewals filed 90 days to one year late; after a year you must take the exam again.
If you fail, you receive a failure report and must apply and pay again. Unemployed applicants may test, and if they pass FDNY issues a temporary letter with their picture; the card is issued once an employer letter is provided.
Whatβs covered
220+ practice questions, by topic
Written from FDNY S-13 / S-14 Standpipe Systems study material (revised March 2024). Every explanation cites its section.
- Holder Duties, Code Rules and Battery Safety28
- Definitions and Standpipe Types29
- Out-of-Service, Tags and Fire Watch46
- Components, Valves, Hose and Signs39
- Inspection, Testing and Maintenance54
- Water Supply, Tanks and Fire Pumps27
Official sources
Facts on this page were checked against these pages in October 2026.
Why people fail
The mistakes that cost people the FDNY S-13 Standpipe Systems
- Not memorizing the inspection, testing and maintenance frequencies: weekly, monthly, quarterly, annual, 3-year and 5-year tasks are easy to mix up.
- Confusing the tags and discs: red, orange, yellow and green tags, and white discs for full outages versus blue discs for partial ones.
- Mixing up standpipe types (wet, dry, manual, automatic, semiautomatic, preaction) and Classes I, II and III.
- Missing the numbers: 300-foot zones, 25 feet above the highest outlet for gravity tanks, two-thirds water in pressure tanks, 40 degrees F, 125-foot hose lines, 5 to 6 feet for hose racks.
- Not knowing who may do what: a plain S-13 holder only inspects, notifies and keeps records; repairs need a master fire suppression piping contractor or a master plumber.
A study plan that works
- Download the March 2024 S-13 / S-14 booklet from FDNY. It is about 90 pages; read one part a day.
- Make flash cards for every frequency in the Part 10 tables, since they produce many questions.
- Practice here by category, starting with Inspection, Testing and Maintenance, then Out-of-Service, Tags and Fire Watch.
- Take timed 50-question tests. Once you score 85 percent, take one at your own pace with 75 questions in mind.
- Before the exam, reread Part 3 on out-of-service systems and the tag and disc colors.
Try a few
Sample FDNY S-13 Standpipe Systems practice questions
Six questions pulled straight from the bank, with the answer shown. For the timed, no-peeking version, use the quiz above.
Why: The booklet cover states that combined sprinkler/standpipe systems also require a valid S-12/S-15. The S-95 covers fire alarm systems and is a different certificate.
Source: FDNY S-13/S-14 Study Material (rev. Mar 2024), Cover page
Why: Preaction systems keep water out of the piping until a release is activated, which suits spaces where accidental water damage would be severe.
Source: FDNY S-13/S-14 Study Material (rev. Mar 2024), Part 7.11
Why: If the hose rack is enclosed in a cabinet, it must swing out at least 90 degrees. A rack that will not do so produces a deficiency.
Source: FDNY S-13/S-14 Study Material (rev. Mar 2024), Part 10.1 (Hose Rack or Storage Device)
Why: A centrifugal pump cannot draw its own water, so the supply (public main or suction tank) must supply positive pressure. A vertical turbine pump is the type that draws water.
Source: FDNY S-13/S-14 Study Material (rev. Mar 2024), Part 9.3.1
Why: For a fully out-of-service system, a red tag goes at the main control valve and one white disc, 8 to 9 inches in diameter, goes on every affected FDC.
Source: FDNY S-13/S-14 Study Material (rev. Mar 2024), Part 3 (Systems Fully Out of Service)
Why: The booklet says the most appropriate course of action is to respond to the fire alarm panel.
Source: FDNY S-13/S-14 Study Material (rev. Mar 2024), Part 8.3
FAQ
FDNY S-13 Standpipe Systems questions, answered
How many questions are on the FDNY S-13 exam?
75 multiple-choice questions with four options each. You need at least 70 percent, which is 53 correct. Our timed practice test uses 50 questions in 90 minutes.
What is the time limit for the S-13?
FDNY says the S-13 is a timed test but does not publish the number of minutes in the booklet. Check with FDNY when you book.
How much does the S-13 cost?
The application fee is $25 and renewal is $15 every three years, as of October 2026. A $25 penalty applies to renewals filed 90 days to one year after expiry.
What is the difference between the S-13 and the S-14?
The S-13 covers standpipe systems. The S-14 is required for personal supervision of multi-zone standpipe systems, where the holder must be immediately available to assist FDNY. Both use the same booklet and the same 75-question test, but the S-14 is a separate, premises-related certificate: you apply for it on its own application with its own $25 fee (as of October 2026), and it is valid only at one location for the person who holds it.
Do I also need an S-12 for a combined system?
Yes. The booklet says combined sprinkler and standpipe systems also require a valid S-12 or S-15.
What can an S-13 holder do without another license?
Visual inspections, notifications and record keeping. Repairs and replacement of components need a master fire suppression piping contractor, or a master plumber for standpipes not combined with sprinklers.
Is this the official FDNY S-13 exam?